Hotel, Commercial, Household Custom Domestic Air Source Household Heating System Heat Pump

Basic Info.Model NO.AHbS06D/IOP-AHbS18D/IOPCertificationSASO, RoHS, CB, CCC, ISO9001, CEWorking MediumR410AHeat Source TypeAir Source Heat PumpCapacity6kw, 8kw, 10kw, 12kw, 14kw, 16kw, 18kwFunctionHot Water, Air Heating, Cooling, Floor HeatingEvaporatorBlue Hydrophilic Aluminum Finned EvaporatorInstallationFreestandingApplicationHotel, Commercial, Household, Ect.Working Ambient Temp.-25ºCTrademarkOUTES/ OEM/ ODMTransport PackageStandard Export PackingSpecification1090mm*485mm*770mmOriginZhejiang, ChinaHS Code8418612090Product DescriptionHotel, Commercial, Household custom domestic air source household heating system heat pumpSpilt EVI DC Inverter Air to Water Heat Pump, Heating & Cooling & Hot WaterProduct DescriptionOUTES :AHbS06D/IOP & AHbS08D/IOP &AHbS10D/IOP & AHbS12D/IOP & AHbS14D/IOP & AHbS16D/IOP & AHbS18D/IOP Domestic Sanitary Hot Water CoolingHeatingCooling+DHWHeating+DHWDC Inverter EVI Compressor Workable at -25ºCAir to water heat pump split type house heating system heat pump whole house application diagram Product ParametersModel AHbS06D/IOPAHbS08D/IOPAHbS10D/IOPAHbS12D/IOPAHbS14D/IOPAHbS16D/IOPAHbS18D/IOPPower Supply/220V~240V/50Hz220V~240V/50Hz220V~240V/50Hz220V~240V/50Hz220V~240V/50Hz220V~240V/50Hz220V~240V/50HzHeating*(A7ºC/W35ºC)Max. Heating CapacitykW6.0 8.0 10.0 12.0 14.0 16.0 17.5 Heating Input PowerkW1.48 2.02 2.43 2.73 3.33 3.95 4.43 Heating Capacity Min./Max.kW2.4/63.2/84.2/105.0/125.4/146.4/167.17/17.5Cooling(A35ºC/W7ºC)Max. Cooling CapacitykW4.5 6.0 7.5 9.0 10.0 12.0 14.0 Cooling Input PowerkW1.48 2.32 2.90 3.05 3.50 4.60 5.76 Cooling Capacity Min./Max.kW1.8/4.52.4/6.03/7.53.6/94.11/105.1/125.8/14Outdoor UnitCompressor/Twin RotaryTwin RotaryTwin RotaryTwin RotaryTwin RotaryTwin RotaryTwin RotaryNoisedB(A)≤58≤58≤60≤58≤58≤60≤60Net Weightkg626565127127132132Net Dimension((L×W×H)mm1090×485×7701090×485×7701090×485×7701095×485×14101095×485×14101095×485×14101095×485×1410Packing Dimension(L×W×H)mm1155×505×8001155×505×8001155×505×8001086×500×15401086×500×15401086×500×15401086×500×1540Indoor UnitHeat Exchanger/PlatePlatePlatePlatePlatePlatePlateWater Pump Brand/optionaloptionaloptionaloptionaloptionaloptionaloptionalRated Water Flowm3/h1.03 1.38 1.72 2.06 2.41 2.75 3.01 Electric HeaterkW3333333NoisedB(A)≤35≤35≤35≤35≤35≤35≤35Net Weightkg45454545454545Net Dimension(L×W×H)mm1015×527×2971015×527×2971015×527×2971015×527×2971015×527×2971015×527×2971015×527×297Packing Dimension(L×W×H)mm1210×638×4561210×638×4561210×638×4561210×638×4561210×638×4561210×638×4561210×638×456Max. Water Outlet TemperatureºC55555555555555Range of Working OperationºC-25~43-25~43-25~43-25~43-25~43-25~43-25~43Refrigerant/ R410A  R410A  R410A  R410A  R410A  R410A  R410A SCOPW/W4.0 4.05 3.9 4.07 4.05 3.95 4.26 ERP Level (35ºC)/A++A++A++A++A++A++A++Container Loading(20'/40'H)Sets54/16254/16254/16227/5427/5427/5427/54Remark:1.Testing Condition:Heating*: Ambient Temp.(DB/WB):7ºC/6ºC,Water Temp.(In/Out):30ºC/35ºC.Heating**: Ambient Temp.(DB/WB):7ºC/6ºC,Water Temp.(In/Out):40ºC/45ºC.Cooling : Ambient Temp.(DB/WB):35ºC/24ºC,Water Temp.(In/Out):12ºC/7ºC.2.The above data test reference EN14825:20163.The data above is only for reference, and  might be changed without prior notice.  Detailed Photos  Other recommendations  About OUTESOUTES was established in 2 0 0 6 with an industry park of 500,000m2, specializing in sales, R&D and manufacturing air conditioner, Cooling & Heating heat pump, Hot Water heat pump, Swimming Pool heat pump, Commercial heat pump, Fan Coils, Air Ventilation Unit, Water Purification Equipment and Pressure Water Tank.OUTES has reputation in domestic market. With 2000 distributors, 1000 After-sales Service Center and 10 local warehouse. Testing Central2007,we set up the 1st testing room, until now, we have 15 testing rooms and 30 test station. The Testing Center is covered 5400m² (six thousand four hundred square meters) and the total investment reach to 50,000,000(fifty million) RMB. We have 40 engineers working here now.2019, we got the approval from CNAS, TUV and BV. So it's more easy for us to test the products exporting to different countries now!We can test the performance, safety, life, noises, stress, transportation and all the other test we need for our products. The products we can test including Hot Water Heat Pump, Chillers, gas system Central Air conditioners, water system Central Air Conditioners, Swimming Pool Heat Pump, Dryers, Air Ventilation Unit and Water Purification Unit. The test capacity from 1 Horse Power to 200 Horse Power for a single Module Machine. The ambient test condition can be from -35ºC to 60ºC.Hot ProductSwimming Pool Heat Pump... ... ... ... ... ... ... ... ... ... ... ... [Click to view]Domestic Heat Pump Water Heater... ... ... ... ... ... ... ... ... ... ... ... [Click to view]Heating/Cooling+Domestic Sanitary Hot Water... ... ... ... ... ... ... ... ... ... ... ... [Click to view]Commercial Heat Pump Water Heater... ... ... ... ... ... ... ... ... ... ... ... [Click to view]Com