Original Gcan Programmable Logic Controller, PLC Price PAC and Dedicated Controller

  Total 3 control modulesHoney! Please confirm your detailed requirements before payment, GCAN-PLC-400 itself does not contain any IO points, if you need different IO modules, please contact us.GCAN-PLC is a modular and scalable PLC module. It consists of a programmable main control module, several I/O modules and a terminal terminal module. Each module communicates with each other using an internal bus, and the user can program and control each I/O module independently. It can be used in almost any industrial field control and acquisition system.ModelCharacteristicCommunication busGCAN-PLC-400CPU frenquency 168M1*CAN+1*Ethernet+1*RS232(or RS485)Program storage:16M byteData storage:512K byteGCAN-PLC-510CPU frenquency 400M1*CAN+1*Ethernet+1*RS232(or RS485)Program storage:32M byteData storage:16M byteGCNA-PLC-511CPU frenquency 400M1*CAN+1*Ethernet+1*RS232+1*RS485Program storage:32M byteData storage:16M byteTotal 2 communication modulesNote: GCAN-IO-8000/8100 is not a PLC main control module, but a remote IO module. GCAN-IO-8000 is a CANopen adapter, and GCAN-IO-8100 is a Modbus RTU adapter.  ModelCharacteristicCommunication busGCAN-IO-8000Protocol:CANopen1*CANNumber of Nodes:1~127Baud rate:10K~1000KMaximum IO module:32GCAN-IO-8100Protocol:Modbus TCP/RTU1*Ethernet+1*RS232+1*RS485Number of Nodes:1~247Baud rate:600~115200Maximum IO module:32PerformanceCANopen adapter(GCAN-IO-8000)Modbus adapter (GCAN-IO-8100)Node number1~1271~247Baud rate10Kbps~1000Kbps600bps~115200bpsPower input24V DC (18~36V)Insert I/O module number32 pieces (at most 32*8 IO point)Dimension100mm*69mm*48mmWorking temperature, humdidness-40ºC~+85ºC, 0~90%RH, without condensationIP gradeIP20Module feature•  Standard CANopen slave station•  Support 4 TPDO, 4 RPDO•  Support 1 SDO, 1 emergency object, 1   node error control object•  Start to perdefine connection, suppor   parameters store•  PDO mode supports synchronization,   looping, event-driven, polling •  Configuration mode is automatic    configuration•  CAN interface: one open 4 terminal•  Input current, 70mA+ ( total GC-bus   current), maximum 2.5A•  Starting current: about 2.5 times   continuous current•  Power contacts: maximum 24V   DC/maximum 10A•  Electrical isolation: 1500 Vrms•  Support standard Modbus protocol, a standard Modus slave station•  Support Modbus function code:01, 02, 03, 04, 05, 06, 15, 16•  Support CRC validation•  Support Modbus TCP, Modbus RTU communication (corresponding to two kinds   of style)•  RS485 interface adopts standard two-wires system•  Serial interface baud rate supports 600bps~115200bps, configured by serial   interface•  The maximum number of bus terminals module is 64•  Configuration mode is automatic configuration, expandedfreely•  Ethernet interface supports static or dynamic IP acquisition•  Ethernet interface supports heartbeat and timeout disconnection•  Ethernetwork interface is fixed, target IP and target interface can be set•  Automatic restoration of connection resources after the Ethernet interface is   disconnected,and reliable establishment of TCP connections•  Ethernet interface is compatible with the SOCKET working mode (TCP Server,          TCP Client,UDP, etc.). The upper computer communication software complies          with the standard SOCKET rules.•  Input current, 70mA+ (total GC-bus current), maximum 4500mA•  Starting current: about 2.5 times continuous current•  Power contacts: maximum 24V DC/maximum 10A•  Electrical isolation: 1000 Vrms (power contact/bus coupled powervoltage)•  Standard DIN rail,designed for industrial designInput and output modules  I/OTypeCharacteristicSignalChannelDigitalGC-1008Digital input(PNP)24V DC8-channelGC-1018Digital input(NPN)24V DC8-channelGC-1502Counter(200kHz max)-2-channelDigitalGC-2008Digital output(PNP)24V DC8-channelGC-2018Digital output(NPN)24V DC8-channelGC-2204Relay output-4-channelGC-2302PWM(20Hz~200kHz)-2-channelAnalog inputGC-3604Voltage input, 16 bits-5~+5V4-channelGC-3624Voltage input, 16 bits10V~+10V4-channelGC-3644Current input, 16 bits0-20mA4-channelGC-3654Current input, 16 bits4-20mA4-channelGC-3664Voltage inptu, 16 bits0~+5V4-channelGC-3674Voltage input, 16 bits0~+10V4-channelGC-38042-wire PT100, 16 bitsThermal resistance4-channelGC-38142-wire PT1000, 16 bitsThermal resistance4-channelGC-38223-wire PT100,16 bitsThermal resistance2-channelGC-38323-wire PT1000,16 bitsThermal resistance2-channelGC-3844K type thermocoupleThermocouple4-channelGC-3854S type tyhermocoupleThermocouple4-channelGC-3864T type thermocoupleThermocouple4-channelGC-3874J type thermocoupleThermocouple4-channelAnalog outputGC-4602Voltage output, 16 bits-5V~+5V2-channelGC-4622Voltage output, 16 bits-10V~+10V2-channelGC-4642Current output, 16 bits0-20mA2-channelGC-4652Current output, 16 bits4-20mA2-channelGC-4662Voltage output, 16 bits0-5V2-channelGC-4672Voltage output, 16 bits0-10V2-channelGC-4674Voltage output, 12 bits0-10V4-channelSpecial moduleGC-6101RS232/RS485 extension--GC-6201GPRS extension--GC-6501WIFI ex