Drinking RO Water Filter System Reverse Osmosis Filtration System Water Purification System Water Filter System

1000Lph ro water system Reverse Osmosis water filter system  ro system Product DescriptionDifferent source water have diffent TDS for  compare and usage. Raw water/ApplicationBottled water,Bag waterCity tap waterBrackish waterSeawaterTDS Range2-10ppm100-1000ppm2000-20000ppm20000-40000ppmDirect DrinkingYesYes/NoNoNoCooking, humanconsumption, washingYesYesNoNoIrrigation, Industry,Animal DrinkingYesYesNoNoReplacement time of consumable partsThere are several kinds of consumables you need to replace regularly, please see below detail.a. Quartz sand: replaced about every 15-18 months. 50kg/bagb. Activated carbon: replaced about every 15-18 months. 25kg/bagc. Resin: replaced about every 15-18 months. 25L/bagd. PP Filter cartridge: replaced about every 1 monthe. Ro membrane: replaced about every 2 year   FeaturesThe process of RO water treatment system (some process is option as per feed water quality)Raw water pump→ mechanical filter(quartz sand filter)→ activated carbon filter→sodium-ion exchanger(water softener)→ security filter→ high pressure pump →Reverse osmosis→ Ozone sterilizer (UV sterilizer).RO Process steps introduction Pre-treatmentFeed water pump, Stainless steel Provide pressure for filters;Quartz sand filterRemove suspended particle and large impurity. In this system;Active Carbon Filter (option)Remove the color, free chloride, organic matter, harmful matter, ect;Anti-scalant systemTo add chemicals to remove some impurities and prolong thememebranes using/washing time(prevent membrane blocking)Manual/Auto control valvesFlushing sand/carbon filter after some time5micron  filterRemove larger than 5 micro colloids in the water. In this system 1micron filterRemove larger than 1 micro colloids in the water. In this systemwater RO Main PartHigh pressure pump, Stainless steel 316LProvide the high pressure to RO membrane;Ro membranesMore than 98% desalination rate, can remove ions except H2O. CIP systemTo washing the membranes when it is blocked after using for long timeElectronic control panelPC controller or PLC controllerRO process flow chart:  (Carbon filter softener based on feed water quality opiton)3000L/hr drinking water filter system                            ModelProductivityMotor powerRecovery rateOutlet water conductivity(us/cm)Raw water conductivityHYRO-500L0.5T/H1.5kw50≤10≤300HYRO-100L1T/H2.2kw50≤10≤300HYRO-2000L2T/H3kw50-60≤10≤300HYRO-3000L3T/H4.5kw55-65≤10≤300HYRO-4000L4T/H6.5kw55-65≤10≤300HYRO-5000L5T/H8kw60-70≤10≤300HYRO-1000L10T/H15kw60-70≤10≤300HYRO-2000L20T/H22kw65-75≤10≤300HYRO-3000L30T/H26kw70-75≤10≤300HYRO-50000L50T/H55kw70-75≤10≤300Large scale water filter system for drinking                                               40m3/hr                                                                           30m3/hr water RO system                                                          Each part function of the drinking water purification system    S/N.  Commodity name                        Application               Remark1Raw water tankStore water, buffering pressure, overcome instability of supplying water by pipe, ensure to supply water stably and continuously for whole systemCustomer provide for themselves, because big size will result in expensive freight.2Raw water pump or called booster pump (feed water pump)Provide needed pressure for every pretreatment filterWe can provide CNP pumps 3Mechanical filter or called quartz sand filter or sand filterWe use fiber glass or stainless steel vessel as housing, fill quarts sand, it can filter big particles impurities, suspended substances, colloids etc.We use China brand or WAVE CYBER brand4Activated carbon filterWe use fiber glass or stainless steel vessel as housing, fill activated carbon, remove color, odor, residual chlorine and organics substances.We use China brand or WAVE CYBER brand5Water softener, demineralizer, or called Na+ exchangerAdopt cation resin to soften water, cation resin will absorb Ca2+, Mg2+(main elements for composing scale), reduce hardness of raw water, System can make resin intelligently regenerate, recyclingWe use China brand or WAVE CYBER brand6Antiscalant dosing system or PH regulating systemDosing antiscalant into feed water, prevent the ro membranes from blocking, prolong the lifetime of RO membranes. Regulating PH to suitable range.Italy SEKO dosing pump or German Prominent7Security filter or pp filter, or called PP sediment filterprevent large particles, bacteria, viruses into RO membrane, accuracy is 5µm Stainless steel housing or PVC housing8High pressure pumpProvide needed working pressure for RO system, ensure production capacity of pure water.CN pump9RO(reverse osmosis) systemCan remove particles, colloids, organic impurities, heavy metal ions, bacteria, virus, heat source etc. harmful substances and 99% dissolved salts.RO membranes USA Filmtec Dow10CIP cleaning systemCleaning RO membranes with chemicals  CNP pumps11Sterilizing deviceUV sterilizer or ozone generatorBNP ozone machine, USA Hanovia UV b