"REACH BOILER" Oil (gas) fired thermal oil boiler is mainly
composed of burner, furnace chamber, circulating oil pump,
expansion oil tank, chimney and control system. Natural gas, LPG or
light diesel fuel is used as fuel, and the open flame is injected
in the furnace chamber to heat the thermal oil. In addition, when
the normal operation of occasional power outages, oil (gas)
heat-conducting oil furnace without the risk of continuous heating
coking of the heat-conducting oil.1. Maximum operating temperature
320 °C.2. Pipe explosion-proof device.3. Oil discharge and return
temperature display.4. Isolated electrical control box to extend
the service life of electrical appliances.5. Hot oil BY-PASS
pressure relief circuit.6. Oil pump horsepower and heating power
can be customized.7. Electrical components mainly adopt OMRON,
FUJI, TE, LS, SIEMENS, ABB, JUMO.8. Adopt skid-mounted type module
design, easy to install and easy to operate.9. Using multi-layer
coils for heat exchange, the heat receiving area is sufficiently
arranged, the surface heat load is low, so that the heat-conducting
oil is not easy to coke and accumulate carbon.10. Fuel in the
furnace for adiabatic combustion, can make the combustion fire
easier, more fully combustion, better improve the thermal
efficiency of the boiler.Model:YY(Q)W Type Gas/Oil
Fired Thermal oil BoilerStructure:Oil Tube Three
PassRated Steam Capacity:0.10-20 ton/hrRated Steam
Pressure:1.0MpaRated Steam Temperature:320°CApplication:Textile
Mill,Food and Beverage,Chemical,Medicine,Light
Industry,Rubber,Printing and Dyeing Plant,Paper Mill,Wood
Processing,Garment and Laundry etc.Model
No.YY(Q)W-120Y(Q)YY(Q)W-240Y(Q)YY(Q)W-350Y(Q)YY(Q)W-500Y(Q)YY(Q)W-700Y(Q)YY(Q)W-1000Y(Q)YY(Q)W-1200Y(Q)YY(Q)W-1400Y(Q)Rated
thermal power(kw)120240350500700100012001400Medium outlet
temperature (ºC)≤350°CApplicable fuelNatural gas/LPG/CNG/Diesel
Oil/Heavy Oil/Waste OilEfficiency≥95%Diesel
Consumption(Kg/h)1225375269100120140Natural Gas
(Nm³/h)1530446383120145170Expansion tank
volume(M3)0.50.51.51.51.5222.5Oil storage tank volume
(M3)112.52.52.5445Weight (t)1.522.63 3.7 55.86.7Overall
dimensions(L*W*D(mm))1650*1050*15201900*1200*19002150*1400*20502200*1400*20503250*1450*22503350*1650*24503800*1750*26004150*1900*2800
Model
No.YY(Q)W-1800Y(Q)YY(Q)W-2100Y(Q)YY(Q)W-2400Y(Q)YY(Q)W-3000Y(Q)YY(Q)W-3500Y(Q)YY(Q)W-47000Y(Q)YY(Q)W-6000Y(Q)YY(Q)W-7000Y(Q)Rated
thermal power(kw)18002100240030003500470060007000Medium outlet
temperature (ºC)≤350°CApplicable fuelNatural gas/LPG/CNG/Diesel
Oil/Heavy Oil/Waste OilEfficiency≥95%Diesel Consumption(Kg/h)180210
244 300350470580680Natural Gas (Nm³/h)220260 290 365 425 570
705780Expansion tank volume(M3)2.52.5333556Oil storage tank volume
(M3)55888101015Weight (t)7.88.89.815.517.821.52527.5Overall
dimensions(L*W*D(mm))4600*2000*30505000*2050*31005000*2250*31006000*2400*34006550*2500*36007300*2600*37007800*3050*38008200*3050*3800Technical
Advantages SafetyBoiler body uses the forced circulation in the
high temperature area to make sure all heating areas can be cooled
down and avoid vaporization; The explosion door and flame detector
are equipped for safe and reliable operation. Comb plates are used
between both sides of boiler and tube bundle to avoid leakage of
condensate and gas caused by using refractory concrete as sealing
material. Air proof test is done before delivery in the factory to
guarantee any gas leakage problem.Environmental protectionBig
combustion chamber equipped with Low emission combustion burner
effectively reduce the NOx to 30mg/m3. Smoke duct and smoke outlet
use internal insulation to reduce operating noise.Combustion
chamber uses full membrane water cooling wall structure and
pressurized combustion without smoke mixture.Energy
conservationGood quality alumina silicate fiber and fire clay
insulation material are used and the boiler body temperature is
controlled below 45ºC and greatly heat loss is reduced. Combustion
chamber is designed with narrow distance tube membrane water
cooling wall which has good air proof to reduce heat lost and
increase boiler thermal efficiency. Internal inspection holes uses
high-alumina refractory and manhole cover seal devices, solving
superheat problem in this part caused by using refractory
bricks.ConvenienceManholes are placed on the front and back side of
drums and inspection doors on back side of boiler easy to open for
inspection and clean inner and outer parts.Longer lifespanMembrane
structure are used in the front and back wall for boiler body and
highly increased their lifespan to over 20 years.The key processes
including material cutting, rolling, drilling are done by advanced
CNC machining process to reduce the assembly stress and extend
boiler service lifetime.Flutter prevention fastener is used for
high temperature part convection tubes, which avoid convection tube
cracking problem.Longitudinal and girth joint adopt advanced
automatic submerged-arc welding for good welding quality. All
longitudinal
Related products about Hot Sale Industrial Thermal Oil Boiler Heat Exchanger for Wall Mounted Gas Boiler Oil Boiler 350kw for Timber Industry
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup